Turn a raw 1H NMR file into a processed spectrum and a written report - peaks, integrals, chemical shifts, multiplicities - ready for a lab notebook or QC record.When to use: a user hands over a raw 1H NMR file (JCAMP/FID) and asks for the processed spectrum plus the peak/integral table.Multi-tool WORKFLOW with processing-parameter and reporting judgment.
Procedure7 steps · 4 orchestrated tools
1
Discover tools via search/get_schema ("read JCAMP", "Fourier transform spectrum",
2
Read the raw file with read_jcamp; state the format found (FID vs already-transformed
Toolsread_jcamp
3
If the data is time-domain, transform it with fft_spectrum; if it is already a spectrum,
Toolsfft_spectrum
4
Handle noise/baseline with smooth_spectrum; report the smoothing parameters used, since
Toolssmooth_spectrum
5
Pick peaks with pick_peaks; set the threshold so the residual solvent and impurity
Toolspick_peaks
6
Build the report: one row per signal with chemical shift (ppm), multiplicity (read from
7
Emit: processed spectrum reference, the peak/integral table, processing parameters, and
You get
processed spectrum (with parameters), peak table (shift, multiplicity, integral,

Overview

A raw 1H NMR file is not a result: it becomes one only after Fourier transform, baseline/noise handling, peak picking, integration and referencing. This skill runs that chain with Paramus spectra tools and finishes with a written report — chemical shifts, multiplicities, integrals — in the form a chemist pastes into a lab notebook. The value is the processing chain plus the reporting judgment, not any single transform.

Guidance vs execution: file reading, FFT, smoothing and peak picking come from tested Paramus spectra tools. Do not hand-roll an FFT or a peak picker in ad-hoc code.

When to Use

  • A raw 1H NMR file (JCAMP-DX or similar) is provided and the question is "process this and give me the spectrum and the peak/integral table"
  • Routine QC / process-analytics reporting where the sample identity is already known and the deliverable is the processed data

Do not use for: verifying that a spectrum matches a named expected compound (that is paramus-nmr-identity-verification), or working out the structure of an unknown from NMR evidence (that is paramus-nmr-unknown-identification). No two skills share a trigger: this skill's trigger is processing-to-report on a file, with no identity question attached.

Domain Judgment

  • Report the processing, not just the result: smoothing strength, peak threshold and the reference assumption are part of the QC record, and two analysts processing the same FID differently must be able to see why their tables differ.
  • Integrals are relative, never absolute: normalize to the integer proton count the structure demands, and flag any signal whose integral deviates by more than ~20% from the nearest integer — that is a purity or exchange question, not a rounding error.
  • A processing report does not identify compounds: assignments are only written when the identity was given up front. If the user starts asking "is this really X?", hand off to the identity-verification skill.

Failure modes

  • File unreadable or wrong nucleus (13C, 31P) → stop and report; do not process a heteronuclear file through a 1H pipeline.
  • FID too short or badly phased → report the spectrum with the phase/reference caveat explicit; the automated phase-correction step is in implementation (nmr-processing).
  • Peak picking returns noise-level garbage (very dilute sample) → raise the threshold, re-run once, and if it persists, report "insufficient signal-to-noise" instead of a table.
  • No spectrum tool reachable → stop and report which step is blocked; a report written without the picked-peak data is a guess and is labelled as such.

Example

Asked: "Here is the 1H NMR of our ethyl acetate batch in CDCl3 — process it and give me the table." The chain runs read_jcamp → fft_spectrum → smooth_spectrum → pick_peaks, and the report reads: quartet at 4.12 ppm (2H, OCH2), singlet at 2.04 ppm (3H, acetyl CH3), triplet at 1.26 ppm (3H, CH3), with integrals normalizing to 2:3:3; the residual CHCl3 signal at 7.26 ppm is reported as the reference signal, not assigned to the sample. The shifts and the 2:3:3 ratio are the standard literature values for ethyl acetate in CDCl3; the claim "matches ethyl acetate" would belong to the identity-verification skill and is deliberately not made here.

Input

raw 1H NMR file (path or content), solvent/reference if known, sample identity if

Output

processed spectrum (with parameters), peak table (shift, multiplicity, integral,

Orchestrates · 4 tools

The skill decides at runtime which to call.

read_jcamp fft_spectrum smooth_spectrum pick_peaks