Additive Specification Qualification

Skill workflow-skill many-tools-to-one-skill Proprietary (Paramus) — guidance only; execution performed by Paramus tools under their own license gating.
provenanceai generated statusuntested
Turn a supplier's Certificate of Analysis or datasheet for a (nano-)additive or raw material into a testable incoming-goods specification - register the certificate, propagate lot-to-lot CoA variability into the property that matters, identify the worst-case lot and its drivers, and lay out the batch-consistency test plan.When to use: a user pastes or files a supplier CoA/datasheet and asks “what do I specify, what do I test, what do I tighten”.Multi-tool WORKFLOW with acceptance-window judgment.
Procedure6 steps · 7 orchestrated tools
1
Discover tools via search/get_schema ("certificate", "CoA", "propagation").
2
Register the supplier document: sustain_upsert_certificate (check what is already
Toolssustain_upsert_certificate
3
Propagate the documented variability: coa_impact_propagation over the lot CoAs
Toolscoa_impact_propagation
4
Add the measurands the CoA does not cover but the application needs: e.g.
5
Write the specification: per measurand the acceptance window derived from the
6
Emit: the specification table, the test plan, the worst-case-lot rationale, and the
You get
the incoming-goods specification (measurands + acceptance windows), the

Overview

Suppliers ship documents, not guarantees: a Certificate of Analysis states what one lot was, not what every lot will be. This skill converts a supplier CoA or datasheet into an incoming-goods specification a formulation can rely on — which measurands, which acceptance windows, which batch-consistency checks — by propagating the documented lot-to-lot spread into the product property the material touches. The value is the chain from document to decision; no single tool call answers it.

Guidance vs execution: certificate registration, CoA propagation, measurements and the test-plan design come from tested Paramus tools. Do not hand-roll statistics or transcribe CoA values by eye into ad-hoc code.

When to Use

  • A supplier CoA/datasheet for an additive, monomer, or nanomaterial arrives and the question is "what do I specify, what do I test, what do I tighten?"
  • A qualification review: is the documented lot spread compatible with the product's property window?

Do not use for: screening a candidate material's properties (that is the selection skill, paramus-nanomaterial-additive-selection), optimizing a formulation (paramus-formulation-property-optimization), or measuring the stability of a finished formulation (paramus-formulation-stability-screen). This skill's trigger is the supplier document; the others start from a material or a recipe.

Domain Judgment

  • A supplier spec is the supplier's promise, not your window: acceptance limits come from what the product tolerates (the propagation result), tightened inside the supplier's range.
  • The fields that dominate the propagation are the fields the spec must control - a CoA line that does not move the product is informational, not a specification.
  • Nanomaterials multiply this: different production routes ship materials with the same name and different performance (the source article's warning for graphene); identity measurands (an optical or structural fingerprint) belong in the spec next to assay numbers.

Failure modes

  • CoA fields missing (no inhibitor or water line) -> say which field is absent and that the propagation is incomplete; do not interpolate supplier documents.
  • No propagation table for the product yet -> deliver the spec skeleton with the propagation step marked open; the acceptance windows then quote the supplier's spec and are labelled as unverified.
  • Registry write fails -> keep the certificate text in the answer and report the registration as failed; never claim a document is on record when it is not.

Example

From the shipped UC09 scenario (paramus-usecases, "Polymer Example (GP Cleared) / Use Case 09 - Raw Material CoA Impact"; photopolymerisation pilot): four lots of Visiomer HEMA 98 (Evonik) with CoA fields assay / water / MEHQ. Lot HEMA-2026-A14's CoA reads assay 99.20 % (spec ≥ 98.0 %), water 410 ppm (spec ≤ 500 ppm), MEHQ 250 ppm (spec 150–300 ppm). Propagating the four lots' CoA spread to the product's molecular weight gives Mw mean 59.4 kDa, std 1.9 kDa, p05 56.3 kDa / p95 62.6 kDa; the worst-case lot is HEMA-2026-A14, driven by high MEHQ (250 ppm) and high water (410 ppm) — both inside the supplier's specification. The resulting incoming spec tightens exactly those two fields: MEHQ < 220 ppm and water < 350 ppm, which holds Mw within ± 1.5 kDa (the scenario's recorded recommendation). The lesson the example encodes: "meets supplier spec" and "safe for your product" are different statements.

Input

supplier CoA/datasheet (text or file) for one or more lots; the product

Output

the incoming-goods specification (measurands + acceptance windows), the