Electrolyte Redox Stability Screen
search/get_schema ("redox", "solvation", "singlebrain_hpc_xtb_solvation_info per candidate for thecloud_rowan_redox per candidate — oxidation andreddb_similar per candidate for the nearestOverview
An electrolyte is a formulated liquid — solvents, salt, additives — and its first gate is whether each molecular component survives the cell's voltage window. This skill screens 1–50 candidate SMILES: oxidation and reduction potentials come from a full thermodynamic cycle (neutral -> cation -> anion) with solvent-phase energies, each candidate is calibrated per class against the nearest measured redox entries, and the result is flagged against four standard windows — standard Li-ion, high-voltage Li-ion, Na-ion, aqueous. The value is the judgment between the tool calls: trusting the cycle, calibrating it, and turning potentials into per-window verdicts.
Guidance vs execution: redox potentials, literature anchoring, and solvation treatment come from tested Paramus tools. Do not hand-roll a thermodynamic cycle or a calibration in ad-hoc code.
When to Use
- A library of candidate electrolyte molecules (solvents, additives, salts — 1 to 50 SMILES) must be ranked for redox stability before any cell is built
- Early formulation decisions: which components survive which voltage window
Do not use for: corrosion protection of coatings
(paramus-corrosion-protection-screen — coating protection, not electrolyte
stability windows) or semiconductor band-gap screening — the triggers do not
touch. No published skill covers battery electrolytes or redox stability; this
skill's trigger is the electrolyte stability-window question.
Domain Judgment
- The thermodynamic cycle is the claim: potentials come from neutral -> cation -> anion in solvent, not from a single HOMO/LUMO lookup; shortcut potentials are labelled as such or not reported.
- Per-class calibration is not optional polish: systematic offsets differ by candidate class, and an uncalibrated ranking can invert the shortlist.
- A measured neighbour beats a computed potential: where
reddb_similarfinds a close measured entry, it anchors the verdict and the computation corroborates. - Window verdicts are per window, not global: the same molecule can be unstable in a high-voltage Li-ion window and stable in an aqueous one — report all four, not a single pass/fail.
Failure modes
- Candidate cannot be parsed (invalid SMILES, salts without a molecular representative) -> stop on that candidate and ask for a valid SMILES; screen the rest and say so.
- No measured neighbour in the redox database -> report the computed potentials with the calibration step marked weak; do not invent a literature anchor.
- Class has no calibration basis -> flag the candidate's verdicts as uncalibrated; never silently apply another class's offset.
- Window bounds undefined for the user's cell -> report potentials against the four standard windows and ask for the custom bounds; do not guess a window.
- Redox tool unavailable -> report which step is blocked and stop; a stability flag without the thermodynamic cycle is a guess and is labelled as such.
Example
Asked: "Screen our standard carbonate solvents — EC, DMC, EMC — for a
high-voltage Li-ion cell; which components are the stability risk?"
The skill treats solvation for each solvent with brain_hpc_xtb_solvation_info
and brain_hpc_xtb_singlepoint, computes oxidation and reduction potentials per
solvent with cloud_rowan_redox via the thermodynamic cycle (neutral -> cation
-> anion), anchors each against the nearest measured redox entries with
reddb_similar, applies per-class calibration for the carbonate class, and flags
each solvent stable / unstable against the four standard windows — standard
Li-ion, high-voltage Li-ion, Na-ion, aqueous. The verdict for a high-voltage
Li-ion target is driven by the oxidation side: the window's upper bound is what
the carbonate solvents must survive, and the per-window table shows where each of
EC, DMC, and EMC stands in all four windows, not only the target one. No numeric
oxidation potentials are quoted here: the governing idea file names EC/DMC/EMC as
the standard carbonate solvents and the four windows as the flag set — those are
the sourceable facts (public documentation of an open-source
computational-chemistry engine, snapshot 2026-10-17, brand-neutral; the
scientific claims only: potentials from the thermodynamic cycle, four standard
windows, per-class calibration) — and this skill invents no measured values.
Input
candidate SMILES (1–50), candidate class per molecule, target voltage
Output
per-candidate table (SMILES, class, raw + calibrated oxidation and
Orchestrates · 4 tools
The skill decides at runtime which to call.
cloud_rowan_redox reddb_similar brain_hpc_xtb_solvation_info brain_hpc_xtb_singlepoint
Frequently Asked Questions
What does Electrolyte Redox Stability Screen do?
Screen a library of candidate electrolyte molecules (1-50 SMILES) for redox stability - oxidation and reduction potentials from a full thermodynamic cycle per candidate, solvation-treated and anchored against measured literature entries - then flag stability against the standard voltage windows (standard Li-ion, high-voltage Li-ion, Na-ion, aqueous). Use when a user names electrolyte candidate molecules and asks which survive which voltage window. Multi-tool WORKFLOW with thermodynamic-cycle, per-class-calibration, and window-verdict judgment.
What do I provide and what do I get back?
You provide: candidate SMILES (1–50), candidate class per molecule, target voltage. You get: per-candidate table (SMILES, class, raw + calibrated oxidation and.
Which tools does it orchestrate?
4 catalog tools, chosen at runtime: cloud_rowan_redox, reddb_similar, brain_hpc_xtb_solvation_info, brain_hpc_xtb_singlepoint.