Electrolyte Redox Stability Screen

Skill workflow-skill many-tools-to-one-skill Proprietary (Paramus) — guidance only; execution performed by Paramus tools under their own license gating.
provenanceai generated statusuntested
Screen a library of candidate electrolyte molecules (1-50 SMILES) for redox stability - oxidation and reduction potentials from a full thermodynamic cycle per candidate, solvation-treated and anchored against measured literature entries - then flag stability against the standard voltage windows (standard Li-ion, high-voltage Li-ion, Na-ion, aqueous).When to use: a user names electrolyte candidate molecules and asks which survive which voltage window.Multi-tool WORKFLOW with thermodynamic-cycle, per-class-calibration, and window-verdict judgment.
Procedure7 steps · 4 orchestrated tools
1
Discover tools via search/get_schema ("redox", "solvation", "single
2
Treat solvation: brain_hpc_xtb_solvation_info per candidate for the
Toolsbrain_hpc_xtb_solvation_info
3
Compute redox potentials: cloud_rowan_redox per candidate — oxidation and
Toolscloud_rowan_redox
4
Anchor against literature: reddb_similar per candidate for the nearest
Toolsreddb_similar
5
Calibrate per class: apply per-class calibration (each candidate class
6
Verdicts: flag each candidate stable / unstable against the four standard
7
Emit the screen: per-candidate table (SMILES, class, raw + calibrated
You get
per-candidate table (SMILES, class, raw + calibrated oxidation and

Overview

An electrolyte is a formulated liquid — solvents, salt, additives — and its first gate is whether each molecular component survives the cell's voltage window. This skill screens 1–50 candidate SMILES: oxidation and reduction potentials come from a full thermodynamic cycle (neutral -> cation -> anion) with solvent-phase energies, each candidate is calibrated per class against the nearest measured redox entries, and the result is flagged against four standard windows — standard Li-ion, high-voltage Li-ion, Na-ion, aqueous. The value is the judgment between the tool calls: trusting the cycle, calibrating it, and turning potentials into per-window verdicts.

Guidance vs execution: redox potentials, literature anchoring, and solvation treatment come from tested Paramus tools. Do not hand-roll a thermodynamic cycle or a calibration in ad-hoc code.

When to Use

  • A library of candidate electrolyte molecules (solvents, additives, salts — 1 to 50 SMILES) must be ranked for redox stability before any cell is built
  • Early formulation decisions: which components survive which voltage window

Do not use for: corrosion protection of coatings (paramus-corrosion-protection-screen — coating protection, not electrolyte stability windows) or semiconductor band-gap screening — the triggers do not touch. No published skill covers battery electrolytes or redox stability; this skill's trigger is the electrolyte stability-window question.

Domain Judgment

  • The thermodynamic cycle is the claim: potentials come from neutral -> cation -> anion in solvent, not from a single HOMO/LUMO lookup; shortcut potentials are labelled as such or not reported.
  • Per-class calibration is not optional polish: systematic offsets differ by candidate class, and an uncalibrated ranking can invert the shortlist.
  • A measured neighbour beats a computed potential: where reddb_similar finds a close measured entry, it anchors the verdict and the computation corroborates.
  • Window verdicts are per window, not global: the same molecule can be unstable in a high-voltage Li-ion window and stable in an aqueous one — report all four, not a single pass/fail.

Failure modes

  • Candidate cannot be parsed (invalid SMILES, salts without a molecular representative) -> stop on that candidate and ask for a valid SMILES; screen the rest and say so.
  • No measured neighbour in the redox database -> report the computed potentials with the calibration step marked weak; do not invent a literature anchor.
  • Class has no calibration basis -> flag the candidate's verdicts as uncalibrated; never silently apply another class's offset.
  • Window bounds undefined for the user's cell -> report potentials against the four standard windows and ask for the custom bounds; do not guess a window.
  • Redox tool unavailable -> report which step is blocked and stop; a stability flag without the thermodynamic cycle is a guess and is labelled as such.

Example

Asked: "Screen our standard carbonate solvents — EC, DMC, EMC — for a high-voltage Li-ion cell; which components are the stability risk?" The skill treats solvation for each solvent with brain_hpc_xtb_solvation_info and brain_hpc_xtb_singlepoint, computes oxidation and reduction potentials per solvent with cloud_rowan_redox via the thermodynamic cycle (neutral -> cation -> anion), anchors each against the nearest measured redox entries with reddb_similar, applies per-class calibration for the carbonate class, and flags each solvent stable / unstable against the four standard windows — standard Li-ion, high-voltage Li-ion, Na-ion, aqueous. The verdict for a high-voltage Li-ion target is driven by the oxidation side: the window's upper bound is what the carbonate solvents must survive, and the per-window table shows where each of EC, DMC, and EMC stands in all four windows, not only the target one. No numeric oxidation potentials are quoted here: the governing idea file names EC/DMC/EMC as the standard carbonate solvents and the four windows as the flag set — those are the sourceable facts (public documentation of an open-source computational-chemistry engine, snapshot 2026-10-17, brand-neutral; the scientific claims only: potentials from the thermodynamic cycle, four standard windows, per-class calibration) — and this skill invents no measured values.

Input

candidate SMILES (1–50), candidate class per molecule, target voltage

Output

per-candidate table (SMILES, class, raw + calibrated oxidation and

Orchestrates · 4 tools

The skill decides at runtime which to call.

cloud_rowan_redox reddb_similar brain_hpc_xtb_solvation_info brain_hpc_xtb_singlepoint